Property ID: RLXSF2
For Rent Php 3,918,600 - Warehouse
Warehouse For Lease in San Fernando, Pampanga (RLX SAN FERNANDO 2)
ADDRESS: Tourism Road, Barangay Malpitic, San Fernando, Pampanga
AVAILABLE WHEN: March 15, 2025
LOT AREA in sqm: 21,450sqm
FLOOR AREA in sqm: 13,995sqm covered
7,455sqm open
LEASE RATE /sqm/month (covered): P280/sqm/mo.
LEASE RATE /sqm/month (open): P80/sqm/mo.
ESCALATION RATE: 5% yearly
SECURITY DEPOSIT: 3 months rent
ADVANCE RENT: 3 months rent
HANDOVER CONDITION (Bare/As-is, where-is): Speculative warehouse, as-is where-is;
Warehouse simultaneously offered;
SPECIFICATIONS/DELIVERABLES: Features Grade A specifications
Floor Specification:
• Warehouse - 200mm thick polished slab with floor hardener;
4,000psi, 1.2 meters high;
• Loading Dock – 200mm thick polished concrete slab with floor
hardener; 4,000psi; 1.2meters high; 5.0 meters wide
• Site Development – 200mm thick concrete slab; 3,000psi
Roofing:
• Warehouse – Big V pre-painted long span G.I sheets with
insulation; skylight; louver ridge ventilation
• Loading Dock – pre-painted rib-type G.I sheets with insulation;
18.0 meters clear span (no columns in between)
Ceiling Height:
• Warehouse – 12.0 meters vertical clearance; exposed
truss/slab
• Loading Dock – 5.0 meters vertical clearance; exposed
truss/slab
Walls:
• Warehouse – 3.4 meters high plastered CHB wall; pre-painted
G.I. sheets with insulation; concrete louvers and insect screen
ventilation
• Perimeter Fence – 3.0 meters high CHB perimeter fence
(painted) with 1.0-meter-high barb wire installation
Security:
• Motorized roll-up doors; Guardhouse with restroom located at
entrance/exit gates.
Back Of House:
• Administration room, Electrical Equipment room, Pump room,
Genset room, Materials Recovery Facility, restrooms
Miscellaneous
• Shed-type driver’s lounge with seating and restroom
Power:
• Local utility provided; 3HP; 400V; 60HZ
Genset:
• Provided with 100% back-up power
Lighting:
• High-bay LED lighting (warehouse and loading bay areas)
Auxiliary:
• Telephone and data conduit only
Plumbing and Sanitary:
• Water and sanitary stub-out only; septic vault (minimum 3
chambers); cistern tank; domestic pump
Fire Protection:
• Upright fire sprinkler system with fire tank; jockey; fire pumps
Fire Detection and Alarm System
• Fire alarm and smoke detectors; fire alarm control panel
located at RLX Administration Office
Others:
• MEPF provision of the following: RLX Office spaces, guard
house Administration room, Electrical Equipment room, Pump
room, Genset room, Materials Recovery Facility, restrooms.
Additional Details
- :